Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Ophthalmol ; 97(5): e719-e728, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30839157

RESUMO

PURPOSE: A retrospective pilot study is conducted to demonstrate the utility of a novel support vector machine learning (SVML) algorithm in a small three-dimensional (3D) sample yielding sparse optical coherence tomography (spOCT) data for the automatic monitoring of neovascular (wet) age-related macular degeneration (wAMD). METHODS: From the anti-vascular endothelial growth factor injection database, 588 consecutive pairs of OCT volumes (57.624 B-scans) were selected in 70 randomly chosen wAMD patients treated with ranibizumab. The SVML algorithm was applied to 183 OCT volume pairs (17.934 B-scans) in 30 patients. Four independent, diagnosis-blinded retina specialists indicated whether wAMD activity was present between 100 pairs of consecutive OCT volumes (9800 B-scans) in the remaining 40 patients for comparison with the SVML algorithm and a non-complex baseline algorithm using only retinal thickness. The SVML algorithm was assessed using inter-observer variability and receiver operating characteristic (ROC) analyses. RESULTS: The retina specialists showed an average Cohen's κ of 0.57 ± 0.13 (minimum: 0.41, maximum: 0.83). The average κ between the proposed algorithm and the retina specialists was 0.62 ± 0.05 and 0.43 ± 0.14 between the baseline algorithm and the retina specialists. Using each of the four retina specialists as the reference, the proposed method showed a superior area under the ROC curve of 0.91 ± 0.03 compared to the ROC 0.81 ± 0.05 shown by the baseline algorithm. CONCLUSION: The SVML algorithm was as effective as the retina specialists were in detecting activity in wAMD. Support vector machine learning (SVML) may be a useful monitoring tool in wAMD suited for small samples that yield sparse OCT data possibly derived from self-measuring OCT-robots.


Assuntos
Algoritmos , Macula Lutea/diagnóstico por imagem , Máquina de Vetores de Suporte , Tomografia de Coerência Óptica/métodos , Degeneração Macular Exsudativa/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...